Качество Гастроскоп Olympus GIF-H170 для ремонта Фабрика

Гастроскоп Olympus GIF-H170 для ремонта

Olympus GIF-H170 gastroscope for repair ► Brief Description Fault: 1. The top left and middle right side with blur image, objective Lens broken. 2. 20% light bundle broken, the small lens turned yellow. 3. Insert tube yellow and wrinkles. 4. The biopsy tube abrasion. 5. The wire and helix tube ...

Качество Гастроскоп OLYMPUS GIF-1TQ160 для ремонта Фабрика

Гастроскоп OLYMPUS GIF-1TQ160 для ремонта

Olympus GIF-1TQ160 gastroscope for repair ► Brief Description Fault: 1.With image, but CCD with broken. 2.Light bundle broken completely. 3.Insert tube abrasion. 4. No biopsy tube. 5. No air&water tube, no water supply tube. 6. No bending section assembly. 7. No digital tip. Solution: Replace CCD, ...

Качество Бронхоскоп Olympus BF-XP160F для ремонта Фабрика

Бронхоскоп Olympus BF-XP160F для ремонта

Olympus BF-XP160F fiber scope for repair ► Brief Description Fault: 1. Image degumming, serious color, CCD aging, a few black and gray spots; 2. 20% of the light bundle is broken; 3. Insert tube aging slightly; 4. Biopsy tube wear, not smooth; 5. Bending section, steel wire, screw tube wear; ...

Качество OLYMPUS CF-H180AL Электронный колоноскоп для ремонта Фабрика

OLYMPUS CF-H180AL Электронный колоноскоп для ремонта

OLYMPUS CF-H180AL Electronic Colonoscope For Repair ► Brief Description Inspection Results: 1. The image is dark, and the CCD is aged. 2. One branch of the light beam is disconnected. 3. The insertion tube is aged and wrinkled. 4. The lower angle is malfunctioning, the other angles are tight, and ...

Качество Олимпус CF-H190L Колоноскоп для ремонта Фабрика

Олимпус CF-H190L Колоноскоп для ремонта

Olympus CF-H190L Colonoscope for repair ► Brief Description Fault: 1. Image ok; 2. Light bundle still ok; 3. The front end of the insert tube is broken, and the serpentine; the position of stress boot is leaking; 4. Biopsy tube wear; 5. Left Angle failure, bending section, wire and helix tube wear; ...

Качество Гастроскоп Olympus GIF-Q150 для ремонта Фабрика

Гастроскоп Olympus GIF-Q150 для ремонта

Olympus GIF-Q150 gastroscope for repair ► Brief Description Fault: 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace light bundle ...

Качество Эндоскоп Olympus TJF-160VR для ремонта Фабрика

Эндоскоп Olympus TJF-160VR для ремонта

Olympus TJF-160VR endoscope for repair ► Brief Description Fault: 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The ...

Качество Гастроскоп OLYMPUS GIF-Q180 для ремонта Фабрика

Гастроскоп OLYMPUS GIF-Q180 для ремонта

Olympus GIF-Q180 gastroscope for repair ► Brief Description Fault: 1.image definition not enough, CCD aging. 2.30% light bundle broken. 3. Insert tube aging and wrinkle. 4.Biopsy tube abrasion. 5. Bending section bited, transformation. 6. Angle not enough, wires and helix tube abrasion. 7. Light ...

Качество Гастроскоп Olympus GIF-H180J для ремонта Фабрика

Гастроскоп Olympus GIF-H180J для ремонта

Olympus GIF-H180J gastroscope for repair ► Brief Description Fault: 1.image with shadow; 2.light bundle broken; 3.insert tube with bite mark; 4.biopsy tube abrasion; 5.bending section serious deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace CCD, ...